Project CAT Plunger pump

The pump set will receive a start/stop command from the main system. The pump set is equipped with a fault contact that can be connected to the main system. The power supply of the pump set will be supplied by the customer and connected up to the control cabinet. This can be a power supply from the main system or directly to the pump set.

When the start command is given from the main system, the set will start at the minimum set speed. Without forced cooling on the electric motor, this will be 25 Hz, which will result in a pump yield of approximately 7.5 l/min. by means of the pressure can be set on the manually operated pressure regulator, our proposal is to set it once at 275 bar. Based on the pressure measurement, the pump set will be kept at 275 bar